Description
ABB PowerValue 11T G2
A cost-effective solution for
maximum power protection
ABB’s PowerValue 11T G2 is a single-phase in/out,
double conversion online uninterruptible power supply (UPS) that guarantees up to 10 kW per single UPS
of clean, reliable power for your critical single-phase
applications. As well as maintaining power to your
server room, advertising display, turnstiles, lab
equipment, transportation signaling systems, ATM
or vending machine, the PowerValue 11T G2 also conditions incoming power to eliminate spikes, swells,
sags, noise and harmonics.
Featuring voltage and frequency independent (VFI)
topology, the tower-only PowerValue 11T G2 saves
costs by minimizing energy losses with its double
conversion efficiency of up to 95 percent (up to 98%
in ECO mode). Two or three units can be connected
in parallel to boost power delivery to a maximum of
30 kW or to provide redundancy.
Simple to install or maintain, inexpensive to run and
with the most compact online UPS footprint available on the market, the PowerValue 11T G2 provides
stable, regulated, transient-free, pure sine wave AC
power with extremely tight output voltage regulation. All units can be fitted with up to four external
battery modules (EBMs) to extend runtime to well
over two hours. Each EBM is dedicated to its corresponding UPS and setup is easily accomplished via
the LCD menu
High reliability
• Double conversion topology protects the load
from all input disturbances
• Parallelable up to three units (6-10k only) to
provide system redundancy
• User replaceable batteries
• Wide input voltage tolerance
Low cost of ownership
• Scalable runtime
• High operating efficiency
• Low installation and upgrading costs
• Compact design
• Output power factor of 1.0 (6-10 kVA only)
Flexible design
• Multiple connectivity options
• Each UPS can be connected with up to four parallel
battery modules for extended runtime
• Adjustable DC voltage and battery charger current
• Extended backup time models available
• Best power density available in the market
segment
Efficient service concept
• Integrated manually operated maintenance bypass
switch (6-10 kVA only)
• Easy setup and maintenance (plug and play)
• User-friendly display
• Remote monitoring options
Product features
The PowerValue 11T G2 with its cost-effective ABB UPS technology makes a high-performance and is now available to market
sectors with lower power requirements: Small server rooms,
critical lab or industrial equipment, security installations and
applications of a similar power class can now profit from one of
12 PowerValue 11T G2 models.
With the most compact online UPS footprint available, the PowerValue 11T G2 features true on-line double conversion. This provides a flexible output frequency and isolates the UPS from upstream disturbances so that the critical load sees only stable,
well-regulated, transient-free, pure sine wave AC power.
A rated output power factor up to 1.0 (kVA = kW) means the
PowerValue 11T G2 delivers 11 percent more active power than a
UPS with a power factor of 0.9. The UPS is optimized for modern IT loads and helps users reduce their energy budget with its
double conversion efficiency of up to 95 percent (up to 98% in
ECO mode).
• Low input line disturbances: input PF ≥ 0.995 @ 100 percent
linear load – THDi < 3 percent
• Flexible configuration for scalable runtime: UPS and EBMs
with and without batteries (long backup)
• Adjustable DC voltage and battery charger current
• Digital charger technology provides accurate charger current
setting and reduces charger ripple current
• The UPS is delivered with an inbuilt parallel board and
paralleling cables. No additional hardware is required for this
installation.
All this with the same guaranteed high availability and quality
standards as ABB’s higher-power premium UPS models – and at
the most attractive entry level price around.
UPS configuration
Standard
• Tower-type, IP20 UPS enclosure
• Single-phase in and out
• Online double conversion UPS
• Paralleling up to three units allows for increase of capacity to
30 kW or redundancy (6-10 kVA only)
• Operator and status LCD
• Wide voltage input frequency range
• Inbuilt batteries (B/B2 versions only)
• Maintenance bypass switch (6-10 kVA only)
• Plug-and-play
Options
• Additional battery cabinets (EBM) for scaling autonomy time
• SNMP, ModBus and AS400 interface cards for remote control
and monitoring of the UPS via a web browser
• Sensors – combined with the network interface card,
environmental humidity and temperature sensors can be
integrated into the system and monitored remotely
• Connectivity functionality via Winpower SNMP (network
management card), mini SNMP, ModBus, mini ModBus, EMP
(environmental monitoring probe), AS400 and mini AS400
Technical specifications
4NWP100164R0002
GENERAL DATA G2 10kVA
Output rated power 10000W
Output power factor 1.0
Topology Online double conversion
Parallel configuration Yes, up to 3 UPS
Inbuilt batteries Yes/Yes/No
INPUT
Nominal input voltage 208/220/230/240 VAC
Input voltage tolerance 100-276 (load dependent)
Input current THDi <3% with full resistive load
Frequency range 45-55Hz / 54-66Hz (extendable to 40~70HZ
at load < 60%)
Power factor ≥0.995
OUTPUT
Rated output voltage 208/220/230/240 VAC
Voltage tolerance ±1% (referred to 230V)
Voltage distortion <1% linear load, <5% non linear load
Overload capacity (linear 10m: 102-125% load
load) on inverter 30s: 126 to 150% load
500 ms: ≥ 150% load
Nominal frequency 50 or 60 Hz
Crest factor 3:1 (load supported)
EFFICIENCY
Overall system efficiency Up to 95%
In eco-mode Up to 98%
ENVIRONMENT
Protection rating IP20
Storage temperature UPS: -25°C to 60°C; Batteries: 0°C to 35°C
Operating temperature 0°-40°C (up to 50°C at 50% load)
Relative humidity 0% to 95%
Altitude (above see level) 1000m without derating
BATTERIES
Type VRLA (valve regulated lead-acid)
Inbuilt batteries 16x9Ah(B)
20x9Ah (B2)
Charging current 0-4A adjustable (B,B2)
0-12 adjustable (S)
Recharge time (inbuilt batteries) 4h to 90%
COMMUNICATIONS
User interface LCD display
Optional communication cards SNMP;ModBus;AS400;Environmental monitoring sensor probe
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Performance IEC/EN 62040-3
Manufacturing ISO 9001:2015, ISO 14001:2015, OHSAS 18001
WEIGHT, DIMENSIONS
Weight 55.2/65.2/15.2 Kg
Dimensions w x h x d B / B2:
225 x 589x 452 mm
S: 225x 348 x 452 mm
—
Warranty *2yrs warranty on parts and service
Reviews
There are no reviews yet.