INVT HR1103S 3kVA / 2700W Online double-conversion UPS 230V

34,600.00

Description

HR11 series is online double-conversion UPS with fully DSP controlled technology. With 19″ standard rack design, self-adjusting output frequency and network management, HR11 is a perfect choice for computers, IT equipments and other sensitive devices.

Application
IDC(Internet Dater Center),network,servers and workstations, control system, communication system, office, PC etc

Features
Wide range of input voltage while input PF>99%
Output PF of 0.9
Full protection of overvoltage, circuit short and over temperature
LCD/LED display, monitoring all the operation status
19″ standard cabinet and battery cabinet
Automatic fan speed adjustment
Abundant interface:RS232,USB, SNMP, Intelligent Card

 

Technical Specs

INPUT

  • Cold Start:  YES, default frequency=50Hz or settable
  • Acceptable Input Voltage:
  • 110VAC~288VAC
  • 100% load@>176VAC
  • 80% load@>154VAC
  • 70% load@>132VAC
  • 50% load@>110VAC

Phase :Single phase in,single phase out

Transfer Voltage Range:

  •    (200VAC/208VAC/220VAC/230VAC/240VAC)
  •     -Line low transfer 110VAC
  •     -Line low recovery 121VAC
  •     -Line high transfer 288VAC
  •     -Line high recovery 281VAC

Input Current

  • Rating(nominal input voltage) : 14.4A
  • Input Power Factor ≥0.97
  • Input Frequency Range 40~70Hz

OUTPUT

Frequency adaptable Settable

Power

  1.  Power(kVA) max : 3
  2.  Power(kW) max3 : 2.7(2.4 for 200VAC/208VAC)

Output Voltage

  •     Waveform(Bat. Mode) Pure Sine Wave
  •     Nominal voltage 200/208/220/230/240VAC
  •     Voltage regulation ± 1 %
  •     Transient response   ≤5% (0% – 100% -0%)
  •     Transient recovery ≤30ms (0% – 100% -0%)
  •     Voltage distortion ≤2% THD, linear load
  • ≤ 5% THD, non-linear load

Output Frequency

  •  Synchronization range ±5Hz default
  •  Battery mode (50±0.1) Hz default
  • Transfer Time
  •  Line mode to battery mode 0
  •  Inverter to bypass 2ms

Efficiency

  •    Line mode with battery full charged : 88%@100% load, 90%@50% load
  •    ECO mode: 97.0%
  •    Battery mode: 87%@100% load, 89%@50% load
  •    Noise(1m away): <45dB@<60%load,60%load
  • Overload Capability(Inverter) 105%~130%: Transfer to bypass after 1 mins.
  • 150%: Transfer to bypass after 30s
  • Overload Capability(Battery Mode) 105%~130%:shutdown after 10s
  • 150%:shutdown after 5s
  • Overload Capability (Bypass Mode) <130%: Long time
  • >130%&<150%:Shutdown after 10min
  • >150%&<180%:Shutdown after 5 seconds
  • Crest Ratio 3:1

BATTERY

  • Rating/Type: 12VDC/7Ah
  • Quantity: 8
  • DC Voltage: 96VDC
  • Back-up Time: 5.5mins @80% load
  • Battery-Low Voltage: 88VDC~94VDC depending on load

INDICATOR & ALARM

  •     Display: LED+LCD
  •     Alarm two short one long
  •     Fault Continuous beeping

INTERFACE

  •     Smart RS232 Standard Cable support INVT Power Monitor Software
  •     SNMP(option) Power Managment from SNMP Manager and Web Browser

OPTION

  • Intelligent Kits DB9 port, dry contact
  • USB B-type USB port
  • SNMP Kits pluggable type
  • Leakage current :<1mA

Charger

  •   Charging voltage : float:109VDC/boost:112VDC
  •   Charging current (max) : 1A
  •   Charging time : 8h recharge to 90%

WARRANTY 2 YEARS / 1 YEAR