Prolink Master Series PRO810-QRL 10KVA /10kW Single Phase online double-conversion Rack/Tower Ups

140,000.00

Description

Master II Series (1P/1P) – Rack/Tower

PROLiNK Master II Series (1P/1P) Rack / Tower Type is a new UPS series with output power factor 1.0. The system design is based on a true online double-conversion technology to optimize system reliability and to deliver clean and high quality electrical power to wide range of critical applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

 

 

 

 

CCTV & Security Systems

Local Area Network (LAN)

Work-Stations

Servers

Emergency Alarm Devices

19” Rack Mount

Prolink Master II Series (1P/1P) Rack / Tower Type is a new UPS series with output power factor 1.0. The system design is based on a true online double-conversion technology to optimize system reliability and to deliver clean and high quality electrical power to wide range of critical applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

DSP control technology is implemented for the UPS ratings 6KVA and above to improve performance and real time harmonic cancellation. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time. Hot swappable battery design is implemented for the UPS ratings from 1KVA to 3KVA.

The front panel LCD display comes with rotation feature which to be used for both rack and tower types. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

PROLiNK Master II series (1P/1P) Rack / Tower- p.f 1.0 Type is available in capacities ranging from 1KVA to 10KVA. Higher charging current is available for 1KVA~3KVA models and it can be set via LCD display.

In addition, Emergency Power Off (EPO) function is also available for the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

Key Features

• True double-conversion
• DSP technology guarantees high performance • Output power factor 1
• Wide input voltage range (110-300 VAC)
• Active input power factor correction 0.99
• 50Hz/60Hz frequency converter mode
• Programmable power management outletsˆ
• Hot swappable battery designˆ
• ECO mode energy saving

ˆOnly available for 1-3KVA

• Emergency power off function (EPO) • Generator compatible
• Adjustable battery numbers
• Optional N+X parallel redundancy

• Adjustable charging current via LCD panel
• Smart battery charger design to optimize battery

performance
• Optional Isolation Transformer Pack for

6kVA and 10kVA

 

GENERAL

UPS Type Rack / Tower
Phase 1 phase in / 1 phase out
Rating (VA) 10000
Nominal Power (W) 10000
Standard ModelDimension (mm) UPS Unit: 610 x 438 x 88 [2U] (D x W x H)Battery Pack: 600 x 438 x 133 [3U] (D x W x H)
Weight (kg) UPS Unit: 20Battery Pack: 63
Long-run ModelDimension (mm) 610 x 438 x 88 [2U] (D x W x H)
Weight (kg) 20

INPUT

Connection Type Terminal
Nominal Voltage 208/220/230/240 VAC VAC
Voltage Range 110~300VAC ± 3% at 50% load176~300VAC ± 3% at 100% load
Frequency Range 46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60Hz
Power Factor ≧0.99
THDi < 4% @100% Load< 6% @50% Load

OUTPUT

Connection Type Terminal
Nominal Voltage 208*/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦1% THD (Linear load)≦4% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*USB Port

Emergency Power Off (EPO)

BATTERY

Standard ModelType 12V / 9Ah
Numbers 20
Typical Recharge Time  9 hours recover to 90% capacity
Long-run ModelType Depending on the capacity of external batteries
Numbers 16 – 20 **
Charging Current (max) 4.0 A

REAR PANEL

  1. Share current port (only available for parallel model)
  2. Parallel port (only available for parallel model)
  3. External battery connector
  4. Intelligent slot
  5. RS-232 communication port
  6. USB communication port
  7. Emergency power off function connector (EPO connector)
  8. Input circuit breaker
  9. Output terminals
  10. Ground
  11. Input terminals
  12. Cooling Fan
  13. External maintenance bypass switch port