Description
Master II Series (1P/1P) – Rack/Tower
PROLiNK Master II Series (1P/1P) Rack / Tower Type is a new UPS series with output power factor 1.0. The system design is based on a true online double-conversion technology to optimize system reliability and to deliver clean and high quality electrical power to wide range of critical applications. High input power factor correction in the system improves the efficiency and reduces overall losses.
CCTV & Security Systems
Local Area Network (LAN)
Work-Stations
Servers
Emergency Alarm Devices
19” Rack Rackmount
Prolink Master II Series (1P/1P) Rack / Tower Type is a new UPS series with output power factor 1.0. The system design is based on a true online double-conversion technology to optimize system reliability and to deliver clean and high quality electrical power to wide range of critical applications. High input power factor correction in the system improves the efficiency and reduces overall losses.
DSP control technology is implemented for the UPS ratings 6KVA and above to improve performance and real time harmonic cancellation. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time. Hot swappable battery design is implemented for the UPS ratings from 1KVA to 3KVA.
The front panel LCD display comes with rotation feature which to be used for both rack and tower types. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.
PROLiNK Master II series (1P/1P) Rack / Tower- p.f 1.0 Type is available in capacities ranging from 1KVA to 10KVA. Higher charging current is available for 1KVA~3KVA models and it can be set via LCD display.
In addition, Emergency Power Off (EPO) function is also available for the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.
Key Features
• True double-conversion
• DSP technology guarantees high performance • Output power factor 1
• Wide input voltage range (110-300 VAC)
• Active input power factor correction 0.99
• 50Hz/60Hz frequency converter mode
• Programmable power management outletsˆ
• Hot swappable battery designˆ
• ECO mode energy saving
ˆOnly available for 1-3KVA
• Emergency power off function (EPO) • Generator compatible
• Adjustable battery numbers
• Optional N+X parallel redundancy
• Adjustable charging current via LCD panel
• Smart battery charger design to optimize battery
performance
• Optional Isolation Transformer Pack for
6kVA and 10kVA
Specifications
GENERAL
UPS Type | Rack / Tower |
Phase | Single phase with ground |
Rating (VA) | 2000 |
Nominal Power (W) | 2000 |
Dimension (mm) | 630 x 438 x 88 (D x W x H) |
Weight (kg) | 10.6 (without battery)23.3 (w/built-int battery) |
INPUT
Connection Type | IEC 320-C20 |
Nominal Voltage | 200/208/220/230/240 VAC |
Voltage Range | 110-300 VAC ± 5% @ 50% load160-300 VAC ± 5% @ 100% load |
Frequency Range | 40Hz ~ 70Hz |
Power Factor | ≧0.99 |
Harmonic Distortion(THDi) | ≦ 5% @ nominal input voltage |
OUTPUT
Connection Type | 8 x IEC 320-C13 |
Nominal Voltage | 200*/208*/220/230/240 VAC |
Voltage Regulation | ±1% |
Frequency Range (Synchronized Range) | 57 ~ 63 Hz or 47 ~ 53 Hz |
Frequency Range (Batt. Mode) | 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz |
Current Crest Ratio | 3:1 (max.) |
Harmonic Distortion | ≦2% THD (Linear load)≦4% THD (Non-linear load) |
ALARM & INDICATORS
Battery Mode | Sounding every 5 seconds |
Low Battery | Sounding every 2 seconds |
Overload | Sounding every second |
Fault | Continuously sounding |
LCD | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
CONNECTIVITY, CONTROL & MONITORING
Front panel | Status LED, Function keys, LCD display |
Communication | Smart RS232*USB Port
Emergency Power Off (EPO) |
BATTERY
Type | 12V / 7Ah |
Numbers | 6 |
Typical Recharge Time | 3 hours recover to 95% capacity for internal battery @2A charging current |
Charging Current | Default 2A, max 8A adjustable |
REAR PANEL
|
Reviews
There are no reviews yet.