Prolink PRO802-QRS 2KVA/ 2000W Single phase with ground online double-conversion Rack/Tower Ups

38,000.00

Description

Master II Series (1P/1P) – Rack/Tower

PROLiNK Master II Series (1P/1P) Rack / Tower Type is a new UPS series with output power factor 1.0. The system design is based on a true online double-conversion technology to optimize system reliability and to deliver clean and high quality electrical power to wide range of critical applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

 

Master II 1P/1P UPS PRO802-QRS | KLIK4IT.COM

 

CCTV & Security Systems

Local Area Network (LAN)

Work-Stations

Servers

Emergency Alarm Devices

19” Rack Rackmount

 

Prolink Master II Series (1P/1P) Rack / Tower Type is a new UPS series with output power factor 1.0. The system design is based on a true online double-conversion technology to optimize system reliability and to deliver clean and high quality electrical power to wide range of critical applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

DSP control technology is implemented for the UPS ratings 6KVA and above to improve performance and real time harmonic cancellation. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time. Hot swappable battery design is implemented for the UPS ratings from 1KVA to 3KVA.

The front panel LCD display comes with rotation feature which to be used for both rack and tower types. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

PROLiNK Master II series (1P/1P) Rack / Tower- p.f 1.0 Type is available in capacities ranging from 1KVA to 10KVA. Higher charging current is available for 1KVA~3KVA models and it can be set via LCD display.

In addition, Emergency Power Off (EPO) function is also available for the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

 

Key Features

• True double-conversion
• DSP technology guarantees high performance • Output power factor 1
• Wide input voltage range (110-300 VAC)
• Active input power factor correction 0.99
• 50Hz/60Hz frequency converter mode
• Programmable power management outletsˆ
• Hot swappable battery designˆ
• ECO mode energy saving

ˆOnly available for 1-3KVA

• Emergency power off function (EPO) • Generator compatible
• Adjustable battery numbers
• Optional N+X parallel redundancy

• Adjustable charging current via LCD panel
• Smart battery charger design to optimize battery

performance
• Optional Isolation Transformer Pack for

6kVA and 10kVA

 

Specifications 

 

GENERAL

UPS Type Rack / Tower
Phase Single phase with ground
Rating (VA) 2000
Nominal Power (W) 2000
Dimension (mm) 630 x 438 x 88 (D x W x H)
Weight (kg) 10.6 (without battery)23.3 (w/built-int battery)

INPUT

Connection Type IEC 320-C20
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC ± 5% @ 50% load160-300 VAC ± 5% @ 100% load
Frequency Range 40Hz ~ 70Hz
Power Factor ≧0.99
Harmonic Distortion(THDi) ≦ 5% @ nominal input voltage

OUTPUT

Connection Type 8 x IEC 320-C13
Nominal Voltage 200*/208*/220/230/240 VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 57 ~ 63 Hz or 47 ~ 53 Hz
Frequency Range (Batt. Mode) 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear load)≦4% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 5 seconds
Low Battery Sounding every 2 seconds
Overload Sounding every second
Fault Continuously sounding
LCD UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*USB Port

Emergency Power Off (EPO)

BATTERY

Type 12V / 7Ah
Numbers 6
Typical Recharge Time  3 hours recover to 95% capacity for internal battery @2A charging current
Charging Current Default 2A, max 8A adjustable

REAR PANEL

  1. Programmable outlets: connect to non-critical loads
  2. Output receptacles: connect to mission-critical loads
  3. AC input
  4. Network/Fax/Modem surge protection
  5. USB communication port
  6. RS-232 communication port
  7. Intelligent slot
  8. Emergency power off function connector (EPO)
  9. External battery connection
  10. Cooling fan
Warranty 2 Years /1 Year Battery